德国IFM真空传感器型号参数资料下载: 产品 测量范围 系统接口 输出功能 电气设计 介质温度 PN2294 -1...10 bar -14.6...145 psi -0.1...1 MPa 1/4 NPT 内螺纹 常开/常闭; (可设定参数); 模拟 PNP/NPN -25...80 °C PN2693 -1...25 bar -14.5...362.5 psi -0.1...2.5 MPa 1/4 NPT 外螺纹 常开/常闭; (可设定参数); 模拟 PNP/NPN -25...80 °C PN2299 -1000...1000 mbar -14.5...14.5 psi -100...100 kPa 1/4 NPT 内螺纹 常开/常闭; (可设定参数); 模拟 PNP/NPN -25...80 °C PN2699 -1000...1000 mbar -14.5...14.5 psi -100...100 kPa 1/4 NPT 外螺纹 常开/常闭; (可设定参数); 模拟 PNP/NPN -25...80 °C PN2694 -1...10 bar -14.6...145 psi -0.1...1 MPa 1/4 NPT 外螺纹 常开/常闭; (可设定参数); 模拟 PNP/NPN -25...80 °C PN2293 -1...25 bar -14.5...362.5 psi -0.1...2.5 MPa 1/4 NPT 内螺纹 常开/常闭; (可设定参数); 模拟 PNP/NPN -25...80 °C PN2569 -500...500 mbar -7.26...7.26 psi -50...50 kPa G 1/4 外螺纹 常开/常闭; (可设定参数); 模拟 PNP/NPN -25...80 °C PN2594 -1...10 bar -14.6...145 psi -0.1...1 MPa G 1/4 外螺纹 常开/常闭; (可设定参数); 模拟 PNP/NPN -25...80 °C PN2593 -1...25 bar -14.5...362.5 psi -0.1...2.5 MPa G 1/4 外螺纹 常开/常闭; (可设定参数); 模拟 PNP/NPN -25...80 °C PN2099 -1000...1000 mbar -14.5...14.5 psi G 1/4 内螺纹 常开/常闭; (可设定参数); 模拟 PNP/NPN -25...80 °C PN2599 -1000...1000 mbar -14.5...14.5 psi G 1/4 外螺纹 常开/常闭; (可设定参数); 模拟 PNP/NPN -25...80 °C PN2094 -1...10 bar -14.6...145 psi -0.1...1 MPa G 1/4 内螺纹 常开/常闭; (可设定参数); 模拟 PNP/NPN -25...80 °C PN2093 -1...25 bar -14.5...362.5 psi -0.1...2.5 MPa G 1/4 内螺纹 常开/常闭; (可设定参数); 模拟 PNP/NPN -25...80 °C PN3094 -1...10 bar -14.5...145 psi -0.1...1 MPa G 1/4 内螺纹 常开/常闭; (可设定参数); 模拟 PNP -25...80 °C PN3529 -1000...0 mbar -14.5...0 psi -29.5...0 inHg -100...0 kPa G 1/4 外螺纹 常开/常闭; (可设定参数); 模拟 PNP -25...80 °C PN3129 -1000...0 mbar -14.5...0 psi -29.5...0 inHg -100...0 kPa G 1/4 内螺纹 常开/常闭; (可设定参数); 模拟 PNP -25...80 °C PN3594 -1...10 bar -14.5...145 psi -0.1...1 MPa G 1/4 外螺纹 常开/常闭; (可设定参数); 模拟 PNP -25...80 °C PN7699 -1000...1000 mbar -14.5...14.5 psi -29.4...29.4 inHg -100...100 kPa 1/4 NPT 外螺纹 常开/常闭; (可设定参数) PNP/NPN -25...80 °C PN7299 -1000...1000 mbar -14.5...14.5 psi -29.4...29.4 inHg -100...100 kPa 1/4 NPT 内螺纹 常开/常闭; (可设定参数) PNP/NPN -25...80 °C PN7694 -1...10 bar -14.5...145 psi -0.1...1 MPa 1/4 NPT 外螺纹 常开/常闭; (可设定参数) PNP/NPN -25...80 °C PN7294 -1...10 bar -14.5...145 psi -0.1...1 MPa 1/4 NPT 内螺纹 常开/常闭; (可设定参数) PNP/NPN -25...80 °C PN7099 -1000...1000 mbar -14.5...14.5 psi -29.4...29.4 inHg -100...100 kPa G 1/4 内螺纹 常开/常闭; (可设定参数) PNP/NPN -25...80 °C PN7599 -1000...1000 mbar -14.5...14.5 psi -29.4...29.4 inHg -100...100 kPa G 1/4 外螺纹 常开/常闭; (可设定参数) PNP/NPN -25...80 °C PN7594 -1...10 bar -14.5...145 psi -0.1...1 MPa G 1/4 外螺纹 常开/常闭; (可设定参数) PNP/NPN -25...80 °C 产品 测量范围 系统接口 输出功能 电气设计 介质温度 PN2294 -1...10 bar -14.6...145 psi -0.1...1 MPa 1/4 NPT 内螺纹 常开/常闭; (可设定参数); 模拟 PNP/NPN -25...80 °C PN2693 -1...25 bar -14.5...362.5 psi -0.1...2.5 MPa 1/4 NPT 外螺纹 常开/常闭; (可设定参数); 模拟 PNP/NPN -25...80 °C PN2299 -1000...1000 mbar -14.5...14.5 psi -100...100 kPa 1/4 NPT 内螺纹 常开/常闭; (可设定参数); 模拟 PNP/NPN -25...80 °C PN2699 -1000...1000 mbar -14.5...14.5 psi -100...100 kPa 1/4 NPT 外螺纹 常开/常闭; (可设定参数); 模拟 PNP/NPN -25...80 °C PN2694 -1...10 bar -14.6...145 psi -0.1...1 MPa 1/4 NPT 外螺纹 常开/常闭; (可设定参数); 模拟 PNP/NPN -25...80 °C PN2293 -1...25 bar -14.5...362.5 psi -0.1...2.5 MPa 1/4 NPT 内螺纹 常开/常闭; (可设定参数); 模拟 PNP/NPN -25...80 °C PN2569 -500...500 mbar -7.26...7.26 psi -50...50 kPa G 1/4 外螺纹 常开/常闭; (可设定参数); 模拟 PNP/NPN -25...80 °C PN2594 -1...10 bar -14.6...145 psi -0.1...1 MPa G 1/4 外螺纹 常开/常闭; (可设定参数); 模拟 PNP/NPN -25...80 °C PN2593 -1...25 bar -14.5...362.5 psi -0.1...2.5 MPa G 1/4 外螺纹 常开/常闭; (可设定参数); 模拟 PNP/NPN -25...80 °C PN2099 -1000...1000 mbar -14.5...14.5 psi G 1/4 内螺纹 常开/常闭; (可设定参数); 模拟 PNP/NPN -25...80 °C PN2599 -1000...1000 mbar -14.5...14.5 psi G 1/4 外螺纹 常开/常闭; (可设定参数); 模拟 PNP/NPN -25...80 °C PN2094 -1...10 bar -14.6...145 psi -0.1...1 MPa G 1/4 内螺纹 常开/常闭; (可设定参数); 模拟 PNP/NPN -25...80 °C PN2093 -1...25 bar -14.5...362.5 psi -0.1...2.5 MPa G 1/4 内螺纹 常开/常闭; (可设定参数); 模拟 PNP/NPN -25...80 °C PN3094 -1...10 bar -14.5...145 psi -0.1...1 MPa G 1/4 内螺纹 常开/常闭; (可设定参数); 模拟 PNP -25...80 °C
PN3529 -1000...0 mbar -14.5...0 psi -29.5...0 inHg -100...0 kPa G 1/4 外螺纹 常开/常闭; (可设定参数); 模拟 PNP -25...80 °C PN3129 -1000...0 mbar -14.5...0 psi -29.5...0 inHg -100...0 kPa G 1/4 内螺纹 常开/常闭; (可设定参数); 模拟 PNP -25...80 °C PN3594 -1...10 bar -14.5...145 psi -0.1...1 MPa G 1/4 外螺纹 常开/常闭; (可设定参数); 模拟 PNP -25...80 °C PN7699 -1000...1000 mbar -14.5...14.5 psi -29.4...29.4 inHg -100...100 kPa 1/4 NPT 外螺纹 常开/常闭; (可设定参数) PNP/NPN -25...80 °C PN7299 -1000...1000 mbar -14.5...14.5 psi -29.4...29.4 inHg -100...100 kPa 1/4 NPT 内螺纹 常开/常闭; (可设定参数) PNP/NPN -25...80 °C PN7694 -1...10 bar -14.5...145 psi -0.1...1 MPa 1/4 NPT 外螺纹 常开/常闭; (可设定参数) PNP/NPN -25...80 °C PN7294 -1...10 bar -14.5...145 psi -0.1...1 MPa 1/4 NPT 内螺纹 常开/常闭; (可设定参数) PNP/NPN -25...80 °C PN7099 -1000...1000 mbar -14.5...14.5 psi -29.4...29.4 inHg -100...100 kPa G 1/4 内螺纹 常开/常闭; (可设定参数) PNP/NPN -25...80 °C PN7599 -1000...1000 mbar -14.5...14.5 psi -29.4...29.4 inHg -100...100 kPa G 1/4 外螺纹 常开/常闭; (可设定参数) PNP/NPN -25...80 °C PN7594 -1...10 bar -14.5...145 psi -0.1...1 MPa G 1/4 外螺纹 常开/常闭; (可设定参数) PNP/NPN -25...80 °C 应用 测量元件 陶瓷电容式压力测量元件 应用 用于工业应用 介质 液体和气体介质 介质温度 [°C] -25...80 抗压强度 1087 psi 75 bar 7.5 MPa 爆破压力zui小值 PN2294 具体参数 2175 psi 150 bar 15 MPa 带显示屏的压力传感器 PN2294具体参数 PN-010-REN14-MFRKG/US/ /V PN2294 真空阻抗 [mbar] -1000 压力 相对压力 允许工作压力的zui大值(用于应用程序符合CRN标准) 725 psi 50 bar 5 MPa 电气数据 工作电压 [V] 18...30 DC; (符合EN 50178 SELV/PELV标准) 电流损耗 [mA] < 35 绝缘电阻zui小值 [MΩ] 100; (500 V DC) 防护等级 III 反相保护 是 开机延迟时间 [s] 0.3 watchdog集成看门狗电路 是 输出 输出数量 2 输出信号 开关信号; 模拟信号; IO-Link; (可配置) 数字输出数量 2 输出功能 常开/常闭; (可设定参数) 开关量输出DC电压降zui大值 [V] 2 开关量输出DC的持续电流负载 [mA] 250 开关频率DC [Hz] < 500 模拟输出数量 1 模拟电流输出 [mA] 4...20; (可调整量程 1:5) 负载zui大值 [Ω] 500 模拟电压输出 [V] 0...10; (可调整量程 1:5) 负载电阻zui小值 [Ω] 2000 电气设计 PNP/NPN 短路保护 是 短路保护类型 脉冲 过载保护 是 测量/设定范围 测量范围 -14.6...145 psi -1...10 bar -0.1...1 MPa 开关点, SP -13.6...145 psi -0.94...10 bar -0.094...1 MPa 复原点, rP -14.2...144.4 psi -0.98...9.96 bar -0.098...0.996 MPa 测量值起点 -14.6...116 psi -1...8 bar -0.1...0.8 MPa 测量值终点 14.6...145 psi 1...10 bar 0.1...1 MPa 设定步距 0.2 psi 0.02 bar 0.002 MPa 精度/偏差 开关点精度 [测量范围值的%] < ± 0,4; (Turn down 1:1) 重复精度 [测量范围值的%] < ± 0,1; (温度波动< 10 K; Turn down 1:1) 特征曲线偏差 [测量范围值的%] < ± 0,25 (BFSL) / < ± 0,5 (LS); (Turn down 1:1; BFSL = Best Fit Straight Line; LS = 极限点设定) 滞后偏差 [测量范围值的%] < ± 0,1; (Turn down 1:1) 长时间稳定性 [测量范围值的%] < ± 0,05; (Turn down 1:1; 每6个月) 温度系数零点 [测量范围值的百分比 / 10 K] 0,2; (-25...80 °C) 温度系数量程 [测量范围值的百分比 / 10 K] 0,2; (-25...80 °C) 反应时间 反应时间 [ms] < 1.5 可编程的延迟时间dS, dr [s] 0...50 用于开关量输出的阻尼dAP [s] 0...4 用于模拟量输出的阻尼 (dAA) [s] 0...4 模拟输出响应时间zui大值 [ms] 3 软件/编程 参数设定 迟滞/窗口; 常开/常闭; ON延迟、关断延时; 阻尼; 显示单位; 电流/电压输出 接口 通信接口 IO-Link 传递类型 COM2 IO-Link revision 1.1 SDCI标准 IEC 61131-9 IO-Link Device ID 473 d / 00 01 d9 h 外形 Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis SIO模式 是 必需的mater port type A 模拟过程数据 1 二位输出过程数据 2 处理周期zui小值 [ms] 2.3 工作条件 环境温度 [°C] -25...80 存储温度 [°C] -40...100 外壳防护等级 IP 65; IP 67 认证/测试 EMC电磁兼容 DIN EN 61000-6-2 DIN EN 61000-6-3 抗冲击 DIN EN 60068-2-27 50 g (11 ms) 抗震 DIN EN 60068-2-6 20 g (10...2000 Hz) MTTF [年] 138 UL认证编号 J012 承压设备指令 良好的工程实践; 可用于第2组流体; 根据需求流体组1的流体 机械技术数据 重量 [g] 222.6 原材料 不锈钢(1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PC 材料(潮湿部件) 不锈钢(1.4404 / 316L); Al2O3 (陶瓷); FKM 开关动作寿命 1亿 拧紧扭矩 [Nm] > 50; (取决于润滑、密封及压力等级) 系统接口 螺纹连接 1/4 NPT 内螺纹 已集成限制器元件 否(可以改装 ) 显示器/操作件 显示 显示单位 3 x LED, 绿色 (bar, psi, MPa) 开关状态 2 x LED, 黄色 测量值 字母数字显示, 红色/绿色 4位数字 注释 包装单位 1 件数 电气连接 |